Windmill Cables
EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable HFEPR/HFEVA 0.6/1kV LSOH Screened Torsion Resistant Power Cable Al Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90℃ more

  Windmill Cables

Indoor/Outdoor PROFIBUS

 

Application

These cables are used in the cell and field area, suitable for indoor or outdoor installation and are equipped with

special PVC or PE sheath.

Standards

DIN 19245 T3

EN 50170

Construction

Windmill Cables

Conductor: Bare copper 1×22AWG.

Insulation: Foam skin PE.

Cable Element: Two cores with filler.

Screen 1: Polyester tape over stranded bundle.

Screen 2: Aluminium/Polyester tape.

Overall Screen: Tinned copper braid.

Sheath: PVC/PE.

Technical Data

Operating Temperatures:-40℃~+70℃

Minimum Bending Radius:120mm

Impedance:150Ohm +/-10%

Maximum Conductor Resistance @20°C:55Ohm/km

Nominal Mutual Capacitance:35nF/km

Minimum Insulation Resistance:1GOhm×km

Attenuation @9.6kHz:<2.5dB/km

Attenuation @38.4kHz:<4dB/km

Attenuation @4kHz:<22dB/km

Attenuation @16kHz:<42dB/km

Flame Retardant:IEC 60332-1/FT 1/FT 4

UV Resistant:Yes

Dimensions and Weight

Construction Nominal Overall Diameter Nominal Weight
No. of cores×mm mm kg/km
1×2×0.64 (PVC Sheath) 8.0 75
1×2×0.64 (PE Sheath) 8.0 65